DONGGUAN ORSTE MACHINERY EQUIPMENT CO., LTD

CN 0769-82020256    189-4860-6110
HomeProducts Center> Industrial Chiller

Air-cooling Industrial Chiller

Mold cooling machine is used to shorten the products molding cycle, it is also applicable in cooling of equipment in order to maintain a required temperature. Besides, it is suitable for other industry fields with similar cooling requirement.

189-4860-6110 / 0769-82020256 Online consultation

product description

Naming Principle

image.png

Features

Cooling range is from 7 to 25 oC.

Insulated water tank is made of stainless steel.

Anti-freezing thermostat is standard equipped.

R22 high-efficient refrigerant is adopted in OCM-A series. Refrigeration loop controlled by high and low pressure switches ensures good cooling effect.

Overload protection is standard equipped for compressor and pump.

Precise temperature controller with an accuracy of ±1 oC is adopted.

Low pressure pump is standard equipment.

Brand compressor with low noise level, low energy-consumption and long service life is employed.

Fin style condenser with excellent heat transfer and rapid cooling is adopted, no need of cooling water.


Application

Mold cooling machine is used to shorten the products molding cycle, it is also applicable in cooling of equipment in order to maintain a required temperature. Besides, it is suitable for other industry fields with similar cooling requirement.


Function Scheme

The compressor starts working when OCM-A mold chilling machine starts up. Refrigerant is compressed into high temperature high pressure gas in the process from B to C, and then be cooled when passing through condenser and changed into liquid. Heat is taken away by the cooling air. In the process from C to D to E and F, liquid refrigerant is dried and filtered by the drier filter. After that, it passes through solenoid valve, level sensor and then reaches the expansion valve. In the process from F to G, the high pressure liquid refrigerant is throttled and depressurized by heat expansion valve and temperature goes down. In the process from G to A, chilled water absorbs the heat of process water in evaporator and returns back to the compressor. This heat exchange process repeats until process water is cooled down to the required temperature.


Hot-air bypass function: the compressor continues working when the process water is cooled down to the required temperature, then the hot-air bypass valve opens as the temperature drops to its set value. A part of the refrigerant from compressor passes through by-pass valve and then reaches evaporator, balancing out part of the machine refrigerating capacity and then goes back to compressor without passing through condenser. With the help of hot-air bypass valve, system can stay in balanced condition and can keep control accuracy within ±1 oC in the meantime. 

image.png

image.png


Parameters

image.png



Previous:No Back to Contents Next:No